{"title":"Safety Switch-RCD","description":null,"products":[{"product_id":"clipsal-mx9rc263-63amp-rcbb-2-pole-30ma-type-a","title":"CLIPSAL MX9RC263 63AMP RCBB 2 Pole 30MA Type A","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMAX9 RCBB 2 Pole 63A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003cp\u003eMX9RC263 is a 2P RCCB with 63A In rated current\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRCD – Residual Current Devices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough Australia has one of the safest electrical systems in the world, accidents can still happen. A poorly maintained appliance, a person who innocently pushes something into a power socket or cuts through an electrical wire, a frayed cord, wet hands or carelessness with power tools are all situations that can lead to serious consequences.\u003cbr\u003e\nThe benefits of residual current devices (RCDs) are well documented and the latest version of wiring rules (AS\/NZS 3000:2018) makes it mandatory to have RCD protection for all final sub-circuits in residential applications.\u003cbr\u003e\nAmendment 2 of AS\/NZS 3000:2018 makes it mandatory to have type A RCD (no type AC RCD) from May 2023 for additional safety. All RCDs under the MAX9 range are future-ready and already type A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow an RCD works\u003c\/strong\u003e\u003cbr\u003e\nThe RCD works by constantly monitoring and comparing the current flow in both the Active and Neutral cables of an electrical installation.\u003cbr\u003e\nDuring normal operation, these Active and Neutral currents are in balance. However, should any current flow to Earth, an imbalance is created in these circuits. If this imbalance is sufficient, the RCD will cut the electrical supply.\u003cbr\u003e\nApart from helping to protect people, RCD will also cut off power to expensive electrical equipment in the event of an electrical fault to Earth. This helps to protect appliances against costly damage and the installation against fire, resulting from faults of this nature.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCovers all potential residential needs – 2 pole and 4 pole variants available\u003c\/li\u003e\n\u003cli\u003eLine and load can be top or bottom connected, ideal when cabling space is restricted or limited\u003c\/li\u003e\n\u003cli\u003eLift-up terminals helps to reduce chances of ‘hot spot’ in terminations with all cable strands are locked in\u003c\/li\u003e\n\u003cli\u003eCompatible with MAX9 18 mm pin type busbar for connections to multiple MCBs\u003c\/li\u003e\n\u003cli\u003eConnection - Upstream\/downstream by tunnel terminal \u0026amp; DIN locking clip\u003c\/li\u003e\n\u003cli\u003ePositive contact indication - Green strip on the toggle that indicates opening of all the poles and allows operations to be performed on the downstream circuit with complete peace of mind\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CablePro","offers":[{"title":"Default Title","offer_id":47090559287551,"sku":"CP-CMX9RC263","price":51.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0769\/0892\/1087\/files\/MX9RC263.jpg?v=1753934648"},{"product_id":"clipsal-mx9rc440-40amp-rcbb-4-pole-30ma-type-a","title":"CLIPSAL MX9RC440 40AMP RCBB 4 Pole 30MA Type A","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMAX9 RCBB 4 Pole 40A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003ch2\u003e\u003c\/h2\u003e\n\u003cp\u003eMX9RC440 is a 4P RCCB with 40A In rated current\u003c\/p\u003e\n\u003cp\u003eAlthough Australia has one of the safest electrical systems in the world, accidents can still happen. A poorly maintained appliance, a person who innocently pushes something into a power socket or cuts through an electrical wire, a frayed cord, wet hands or carelessness with power tools are all situations that can lead to serious consequences.\u003cbr\u003e\nThe benefits of residual current devices (RCDs) are well documented and the latest version of wiring rules (AS\/NZS 3000:2018) makes it mandatory to have RCD protection for all final sub-circuits in residential applications.\u003cbr\u003e\nAmendment 2 of AS\/NZS 3000:2018 makes it mandatory to have type A RCD (no type AC RCD) from May 2023 for additional safety. All RCDs under the MAX9 range are future-ready and already type A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow an RCD works\u003c\/strong\u003e\u003cbr\u003e\nThe RCD works by constantly monitoring and comparing the current flow in both the Active and Neutral cables of an electrical installation.\u003cbr\u003e\nDuring normal operation, these Active and Neutral currents are in balance. However, should any current flow to Earth, an imbalance is created in these circuits. If this imbalance is sufficient, the RCD will cut the electrical supply.\u003cbr\u003e\nApart from helping to protect people, RCD will also cut off power to expensive electrical equipment in the event of an electrical fault to Earth. This helps to protect appliances against costly damage and the installation against fire, resulting from faults of this nature.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCovers all potential residential needs – 2 pole and 4 pole variants available\u003c\/li\u003e\n\u003cli\u003eLine and load can be top or bottom connected, ideal when cabling space is restricted or limited\u003c\/li\u003e\n\u003cli\u003eLift-up terminals helps to reduce chances of ‘hot spot’ in terminations with all cable strands are locked in\u003c\/li\u003e\n\u003cli\u003eCompatible with MAX9 18 mm pin type busbar for connections to multiple MCBs\u003c\/li\u003e\n\u003cli\u003eConnection - Upstream\/downstream by tunnel terminal \u0026amp; DIN locking clip\u003c\/li\u003e\n\u003cli\u003ePositive contact indication - Green strip on the toggle that indicates opening of all the poles and allows operations to be performed on the downstream circuit with complete peace of mind\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CablePro","offers":[{"title":"Default Title","offer_id":47090559418623,"sku":"CP-CMX9RC440","price":49.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0769\/0892\/1087\/files\/MX9RC440.jpg?v=1753934652"},{"product_id":"clipsal-mx9rc240-40amp-rcbb-2-pole-30ma-type-a","title":"CLIPSAL MX9RC240 40AMP RCBB 2 Pole 30MA Type A","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMAX9 RCBB 2 Pole 40A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMX9RC240 is a 2P RCCB with 40A In rated current\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRCD – Residual Current Devices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough Australia has one of the safest electrical systems in the world, accidents can still happen. A poorly maintained appliance, a person who innocently pushes something into a power socket or cuts through an electrical wire, a frayed cord, wet hands or carelessness with power tools are all situations that can lead to serious consequences.\u003cbr\u003e\nThe benefits of residual current devices (RCDs) are well documented and the latest version of wiring rules (AS\/NZS 3000:2018) makes it mandatory to have RCD protection for all final sub-circuits in residential applications.\u003cbr\u003e\nAmendment 2 of AS\/NZS 3000:2018 makes it mandatory to have type A RCD (no type AC RCD) from May 2023 for additional safety. All RCDs under the MAX9 range are future-ready and already type A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow an RCD works\u003c\/strong\u003e\u003cbr\u003e\nThe RCD works by constantly monitoring and comparing the current flow in both the Active and Neutral cables of an electrical installation.\u003cbr\u003e\nDuring normal operation, these Active and Neutral currents are in balance. However, should any current flow to Earth, an imbalance is created in these circuits. If this imbalance is sufficient, the RCD will cut the electrical supply.\u003cbr\u003e\nApart from helping to protect people, RCD will also cut off power to expensive electrical equipment in the event of an electrical fault to Earth. This helps to protect appliances against costly damage and the installation against fire, resulting from faults of this nature.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCovers all potential residential needs – 2 pole and 4 pole variants available\u003c\/li\u003e\n\u003cli\u003eLine and load can be top or bottom connected, ideal when cabling space is restricted or limited\u003c\/li\u003e\n\u003cli\u003eLift-up terminals helps to reduce chances of ‘hot spot’ in terminations with all cable strands are locked in\u003c\/li\u003e\n\u003cli\u003eCompatible with MAX9 18 mm pin type busbar for connections to multiple MCBs\u003c\/li\u003e\n\u003cli\u003eConnection - Upstream\/downstream by tunnel terminal \u0026amp; DIN locking clip\u003c\/li\u003e\n\u003cli\u003ePositive contact indication - Green strip on the toggle that indicates opening of all the poles and allows operations to be performed on the downstream circuit with complete peace of mind\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CablePro","offers":[{"title":"Default Title","offer_id":47090560237823,"sku":"CP-CMX9RC240","price":38.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0769\/0892\/1087\/files\/MX9RC240.jpg?v=1753934655"},{"product_id":"clipsal-mx9rc463-63amp-rcbb-4-pole-30ma-type-a","title":"CLIPSAL MX9RC463 63AMP RCBB 4 Pole 30MA Type A","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eMAX9 RCBB 4 Pole 63A\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eMX9RC463 is a 4P RCCB with 63A In rated current\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eRCD – Residual Current Devices\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eAlthough Australia has one of the safest electrical systems in the world, accidents can still happen. A poorly maintained appliance, a person who innocently pushes something into a power socket or cuts through an electrical wire, a frayed cord, wet hands or carelessness with power tools are all situations that can lead to serious consequences.\u003cbr\u003e\nThe benefits of residual current devices (RCDs) are well documented and the latest version of wiring rules (AS\/NZS 3000:2018) makes it mandatory to have RCD protection for all final sub-circuits in residential applications.\u003cbr\u003e\nAmendment 2 of AS\/NZS 3000:2018 makes it mandatory to have type A RCD (no type AC RCD) from May 2023 for additional safety. All RCDs under the MAX9 range are future-ready and already type A.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eHow an RCD works\u003c\/strong\u003e\u003cbr\u003e\nThe RCD works by constantly monitoring and comparing the current flow in both the Active and Neutral cables of an electrical installation.\u003cbr\u003e\nDuring normal operation, these Active and Neutral currents are in balance. However, should any current flow to Earth, an imbalance is created in these circuits. If this imbalance is sufficient, the RCD will cut the electrical supply.\u003cbr\u003e\nApart from helping to protect people, RCD will also cut off power to expensive electrical equipment in the event of an electrical fault to Earth. This helps to protect appliances against costly damage and the installation against fire, resulting from faults of this nature.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003eFeatures and benefits\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eCovers all potential residential needs – 2 pole and 4 pole variants available\u003c\/li\u003e\n\u003cli\u003eLine and load can be top or bottom connected, ideal when cabling space is restricted or limited\u003c\/li\u003e\n\u003cli\u003eLift-up terminals helps to reduce chances of ‘hot spot’ in terminations with all cable strands are locked in\u003c\/li\u003e\n\u003cli\u003eCompatible with MAX9 18 mm pin type busbar for connections to multiple MCBs\u003c\/li\u003e\n\u003cli\u003eConnection - Upstream\/downstream by tunnel terminal \u0026amp; DIN locking clip\u003c\/li\u003e\n\u003cli\u003ePositive contact indication - Green strip on the toggle that indicates opening of all the poles and allows operations to be performed on the downstream circuit with complete peace of mind\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"CablePro","offers":[{"title":"Default Title","offer_id":47090560368895,"sku":"CP-CMX9RC463","price":66.0,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0769\/0892\/1087\/files\/MX9RC463.jpg?v=1753934659"},{"product_id":"rcd-2-pole-40a","title":"RCD - 2 POLE 40A","description":"\u003cul\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eComplete din rail mount 2 Pole RCCB, with a trip rate of 30mA and automatic cut off on current leakage.\u003c\/p\u003e\n\u003cp\u003eAvailable in 40 \u0026amp; 63Amp\u003c\/p\u003e\n\u003cp\u003eComplete din rail mount 2 Pole RCCB, with a trip rate of 30mA and automatic cut off on current leakage.\u003c\/p\u003e\n\u003cp\u003eAvailable in 40A.\u003c\/p\u003e\n\u003cp\u003ePoles Number: 2P\u003c\/p\u003e\n\u003cp\u003eApplicable to terminal and pin\/fork type busbar connection.\u003c\/p\u003e\n\u003cp\u003eEquipped with finger protected connection terminals.\u003c\/p\u003e\n\u003cp\u003eAdopt electromagnetic style release , can play a leak electricity and electric shock protecting role while breaking in zero Line.\u003c\/p\u003e\n\u003cp\u003eMaterial: Fire resistant plastic parts\u003c\/p\u003e\n\u003cp\u003eApplication: Automatically disconnect the circuit when earth fault\/leakage current occurs and exceeds the rated sensitivity Independent of power supply and line voltage, and free from external interference, voltage fluctuation.\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e****Please note brands supplied will be either Pulset, Transco or Tesla. All are Australian Certified.****\u003c\/p\u003e","brand":"CablePro","offers":[{"title":"Default Title","offer_id":47090721947903,"sku":"CP-RCD2\/40","price":36.39,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0769\/0892\/1087\/files\/2-pole-40A1.jpg?v=1753937932"},{"product_id":"rcd-4-pole-63a","title":"RCD - 4 POLE 63A","description":"\u003cp\u003eRCD – 4 POLE 63A\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e4 Pole 63A RCD 30mA 240V\u003c\/li\u003e\n\u003cli\u003eDin Rail Mounting,with a trip rate of 30mA and automatic cut off on current leakage.\u003c\/li\u003e\n\u003cli\u003eStandard Size fits most switchboards and enclosure\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eComplete din rail mount 4 Pole RCCB, with a trip rate of 30mA and automatic cut off on current leakage.\u003c\/p\u003e\n\u003cp\u003eAvailable in 40 \u0026amp; 63Amp\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eComplete din rail mount 2\u0026amp;4 Pole RCCB, with a trip rate of 30mA and automatic cut off on current leakage.\u003c\/p\u003e\n\u003cp\u003eAvailable in 40A and 63A.\u003c\/p\u003e\n\u003cp\u003ePoles Number: 4P\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e****Please note brands supplied will be either Pulset, Transco or Tesla. All are Australian Certified.****\u003c\/p\u003e","brand":"CablePro","offers":[{"title":"Default Title","offer_id":47090729353471,"sku":"CP-RCD4\/63","price":51.5,"currency_code":"AUD","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0769\/0892\/1087\/files\/4-pole_9a480624-2a73-49cd-ad9b-f0e78f5e2bac.jpg?v=1753938250"},{"product_id":"rcd-4-pole-40a","title":"RCD - 4 POLE 40A","description":"\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eComplete din rail mount 4 Pole RCCB, with a trip rate of 30mA and automatic cut off on current leakage.\u003c\/p\u003e\n\u003cp\u003eAvailable in 40 \u0026amp; 63Amp\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003eComplete din rail mount 2\u0026amp;4 Pole RCCB, with a trip rate of 30mA and automatic cut off on current leakage.\u003c\/p\u003e\n\u003cp\u003eAvailable in 40A and 63A.\u003c\/p\u003e\n\u003cp\u003ePoles Number: 4P\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e\n\u003cp\u003e****Please note brands supplied will be either Pulset, Transco or Tesla. All are Australian Certified.****\u003c\/p\u003e","brand":"CablePro","offers":[{"title":"Default Title","offer_id":47090729451775,"sku":"CP-RCD4\/40","price":44.0,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0769\/0892\/1087\/files\/4-pole_afb62e05-2ac2-4b91-b4a0-a9b8ce2fc5bd.jpg?v=1753938254"},{"product_id":"rcd-2-pole-63a","title":"RCD - 2 POLE 63A","description":"\u003cul\u003e\n\u003cli\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003cp\u003eComplete din rail mount 2 Pole RCCB, with a trip rate of 30mA and automatic cut off on current leakage.\u003c\/p\u003e\n\u003cp\u003eAvailable in 40 \u0026amp; 63Amp\u003c\/p\u003e\n\u003cp\u003eComplete din rail mount 2 Pole RCCB, with a trip rate of 30mA and automatic cut off on current leakage.\u003c\/p\u003e\n\u003cp\u003ePoles Number: 2P\u003c\/p\u003e\n\u003cp\u003eApplicable to terminal and pin\/fork type busbar connection.\u003c\/p\u003e\n\u003cp\u003eEquipped with finger protected connection terminals.\u003c\/p\u003e\n\u003cp\u003eAdopt electromagnetic style release , can play a leak electricity and electric shock protecting role while breaking in zero Line.\u003c\/p\u003e\n\u003cp\u003eMaterial: Fire resistant plastic parts\u003c\/p\u003e\n\u003cp\u003eApplication: Automatically disconnect the circuit when earth fault\/leakage current occurs and exceeds the rated sensitivity Independent of power supply and line voltage, and free from external interference, voltage fluctuation.\u003c\/p\u003e\n\u003cp\u003e****Please note brands supplied will be either Pulset, Transco or Tesla. All are Australian Certified.****\u003c\/p\u003e\n\u003cp\u003e \u003c\/p\u003e","brand":"CablePro","offers":[{"title":"Default Title","offer_id":47090729681151,"sku":"CP-RCD2\/63","price":38.73,"currency_code":"AUD","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0769\/0892\/1087\/files\/2-pole-40A1_d01c2b8d-88a7-4299-88ed-f8bd2bd6e3dd.jpg?v=1753938261"}],"url":"https:\/\/dcselectrical.net.au\/collections\/safety-switch-rcd.oembed","provider":"DCS Electrical Supplies","version":"1.0","type":"link"}